Pillow block bearing sizes are identified by nominal shaft bore diameter, but housing dimensions also determine whether a unit will fit. The UCP200 size charts below cover metric and inch-bore units, including shaft diameter (d), center height (H), housing length (L) and nominal mounting-hole spacing (J).

Quick Answer

Metric — UCP205

25 mm

Nominal shaft diameter

Inch — UCP205-16

25.4 mm

1-inch nominal shaft diameter

The nominal bore difference is 0.4 mm. These bore sizes are not interchangeable. For replacement, check the full model number, shaft tolerance and mounting dimensions before ordering.

Pillow Block Bearing Size Chart (Metric and Inch)

These are reference dimensions for conventional UCP200 cast-iron, set-screw mounted bearing units. Nominal housings and accessories can differ by manufacturer or configuration. Dimensions are not manufacturing tolerances; consult the drawing of the exact product you plan to use.

UCP200 Series Size Chart (Metric)

Unit

Bore d (mm)

Center H (mm)

Length L (mm)

Bolt J (mm)

Bolt

UCP201

12

30.2

127

95

M10

UCP202

15

30.2

127

95

M10

UCP203

17

30.2

127

95

M10

UCP204

20

33.3

127

95

M10

UCP205

25

36.5

140

105

M10

UCP206

30

42.9

165

121

M14

UCP207

35

47.6

167

127

M14

UCP208

40

49.2

184

137

M14

UCP209

45

54

190

146

M14

UCP210

50

57.2

206

159

M16

UCP211

55

63.5

219

171

M16

UCP212

60

69.8

241

184

M16

UCP213

65

76.2

265

203

M20

UCP214

70

79.4

266

210

M20

UCP215

75

82.6

275

217

M20

Data note: Nominal UCP200 envelope dimensions are cross-checked against published NTN-SNR bearing-unit references. UCP212 uses H 69.8 mm, L 241 mm and J 184 mm; UCP213 uses H 76.2 mm, L 265 mm and J 203 mm; UCP214 uses H 79.4 mm, L 266 mm and J 210 mm. The final product drawing governs fit and interchangeability.

UCP200 Series Size Chart (Inch Bore)

Inch-bore suffixes commonly specify the bore in sixteenths of an inch; some catalogs use a three-digit alternative such as -100 for 1 in. The H, L and J columns below are approximate conversions of the metric-family reference dimensions, not measured inch-product specifications. Actual catalog dimensions and available suffixes may differ.

Unit

Bore (fraction)

Bore (decimal in)

Bore (mm)

H (in)

L (in)

J (in)

UCP201-8

1/2"

0.500"

12.7

1.189

5.000

3.740

UCP202-9

9/16"

0.5625"

14.2875

1.189

5.000

3.740

UCP202-10

5/8"

0.625"

15.875

1.189

5.000

3.740

UCP203-11

11/16"

0.6875"

17.4625

1.189

5.000

3.740

UCP204-12

3/4"

0.750"

19.05

1.311

5.000

3.740

UCP205-13

13/16"

0.8125"

20.6375

1.437

5.512

4.134

UCP205-14

7/8"

0.875"

22.225

1.437

5.512

4.134

UCP205-15

15/16"

0.9375"

23.8125

1.437

5.512

4.134

UCP205-16 / UCP205-100

1"

1.000"

25.4

1.437

5.512

4.134

UCP206-101

1-1/16"

1.0625"

26.9875

1.689

6.496

4.764

UCP206-102

1-1/8"

1.125"

28.575

1.689

6.496

4.764

UCP206-103

1-3/16"

1.1875"

30.1625

1.689

6.496

4.764

UCP206-104

1-1/4"

1.250"

31.75

1.689

6.496

4.764

UCP207-104

1-1/4"

1.250"

31.75

1.874

6.575

5.000

UCP207-105

1-5/16"

1.3125"

33.3375

1.874

6.575

5.000

UCP207-107

1-7/16"

1.4375"

36.5125

1.874

6.575

5.000

UCP208-108

1-1/2"

1.500"

38.1

1.937

7.244

5.394

UCP208-109

1-9/16"

1.5625"

39.6875

1.937

7.244

5.394

UCP209-110

1-5/8"

1.625"

41.275

2.126

7.480

5.748

UCP209-112

1-3/4"

1.750"

44.45

2.126

7.480

5.748

UCP210-114

1-7/8"

1.875"

47.625

2.252

8.110

6.260

UCP210-200

2"

2.000"

50.8

2.252

8.110

6.260

UCP211-203

2-3/16"

2.1875"

55.5625

2.500

8.622

6.732

UCP215-48

3"

3.000"

76.2

3.252

10.827

8.543

Note: UCP206-104 and UCP207-104 both have a 1-1/4 in nominal bore but use different housings. A matching bore does not establish housing interchangeability. Verify the bolt size and hole geometry in the product drawing.

UCP205, UCP206, UCP207 and UCP208 Housing Dimensions

The following values come from the linked LILY product specifications. Use these catalog dimensions rather than the converted reference values when selecting these particular units.

LILY model

Bore

H

L

Bolt center range

Bolt

UCP205

25 mm

36.5 mm

140 mm

95–114 mm

M10

UCP205-16

1 in

1.4375 in

5.5 in

3.75–4.5 in

3/8 in

UCP206

30 mm

42.9 mm

165 mm

113–129 mm

M14

UCP207

35 mm

47.6 mm

167 mm

119–135 mm

M14

UCP208

40 mm

49.2 mm

184 mm

124–149 mm

M14

The bolt center range is the minimum and maximum center-to-center spacing listed in the product catalog, not a tolerance on the nominal J dimension. Check mounting-slot geometry and fastener clearance as well.

Key Pillow Block Bearing Dimensions Explained

Bore (d) is the nominal shaft diameter. Center height (H) is measured from the housing mounting surface to the shaft centerline. J is the nominal center-to-center mounting-hole spacing; slotted holes may allow a range of bolt positions. Housing length (L) is the overall base length.

Engineering diagram of pillow block bearing showing dimensions d bore diameter, H center height, L housing length, J bolt spacing, A housing width, and S bolt size

Dimension

Symbol

Selection check

Shaft bore

d

Match the measured shaft and specified fit

Center height

H

Maintain the intended shaft centerline

Bolt-hole spacing

J

Match the existing mounting pattern

Overall housing length

L

Check clearance on the machine frame

Housing width / bolt slots

A / N

Check mounting footprint and fastener clearance

Symbols are not universal across all catalogs: compare the dimension drawing, not only its letter codes. A nominal difference in H or J can prevent drop-in replacement even when two units accept the same shaft.

How to Read a Pillow Block Bearing Model Number

UCP205 is commonly assembled from a UC205 insert bearing and P205 pillow-block housing. In this family, 05 identifies a nominal 25 mm bore; UCP206 corresponds to 30 mm and UCP207 to 35 mm. UCP201 (12 mm), UCP202 (15 mm) and UCP203 (17 mm) are exceptions to the size-code-times-five rule.

Anatomy of a pillow block bearing model number UCP205-16 showing UC insert type, P housing, 200 series, 05 bore code, and -16 inch suffix

For inch variants, check the full designation: UCP205-14 denotes 7/8 in and UCP205-16 denotes 1 in under the sixteenths convention. In catalogs using the three-digit convention, -107 denotes 1-7/16 in. A UC size chart describes the insert bearing, including bore, outside diameter and ring widths; a UCP size chart describes the complete mounted unit, including housing and mounting dimensions.

Other Common Mounted-Bearing Prefixes

Prefix

Typical configuration

UCP

Two-bolt pillow block

UCPA

Tapped-base pillow block

UCPH

Higher-center pillow block

UCF

Four-bolt square flange

UCFL

Two-bolt oval flange

UCT

Take-up unit

Pillow Block vs. Flange Units: Selection Guide

How to Measure Pillow Block Bearings

1

Measure the Shaft Diameter

Isolate the equipment and prevent unintended movement. Measure the shaft at more than one axial location and in two perpendicular directions using a calibrated micrometer. Check for wear, taper and out-of-roundness; do not round an unknown shaft to the nearest nominal inch or millimeter.

2

Measure the Center Height

Measure the perpendicular distance from the mounting surface to the shaft centerline (H). If the shaft is parallel to the mounting surface, measure vertically to its top and subtract half the shaft diameter.

Center height calculation

H = T − d/2

H = 49.0 − 25.0/2 = 36.5 mm

T is the distance from the mounting surface to the top of the shaft; d is the shaft diameter. The shaft axis must be parallel to the mounting surface.

3

Check Mounting Dimensions

Measure the mounting-bolt centers (J), housing length (L), base and slot clearances. Compare the results with the exact product drawing.

4

Identify the Bearing and Housing

Record the full insert and housing designations, including any bore or locking suffixes. A housing marking alone does not establish shaft size.

5

Check Operating Requirements

Compare shaft fit, locking method, bearing load rating, operating speed and sealing arrangement. An accurate nominal bore by itself is not enough to select a safe substitute.

A 3/4 in shaft measures 19.05 mm, and a 1-1/2 in shaft measures 38.1 mm. Neither should be rounded to the nearest metric bore when selecting a replacement.

UCP200 vs. UCP300: What Changes?

For the same nominal shaft bore, a UCP300-family unit generally uses a larger insert and housing than its UCP200 counterpart. As a documented example, an NTN-SNR UCP205 has H = 36.5 mm, J = 105 mm and L = 140 mm, whereas NTN-SNR UCP305 has H = 45 mm, J = 132 mm and L = 175 mm. These are manufacturer-specific reference dimensions, not a universal interchangeability guarantee.

NTN-SNR reference

UCP205

UCP305

Nominal shaft bore

25 mm

25 mm

Center height H

36.5 mm

45 mm

Bolt spacing J

105 mm

132 mm

Housing length L

140 mm

175 mm

Do not change series using a fixed percentage of the catalog dynamic load rating. Bearing life and suitability depend on the equivalent load, speed, operating conditions, reliability requirement and the manufacturer’s rating method. Check the actual housing footprint before assuming a larger series will fit.

Load Capacity and Performance of Pillow Block Bearings

Shaft Fit, Surface Condition and Installation

Shaft tolerance depends on the insert, locking system, loading and manufacturer. Set-screw mounted inserts, eccentric-lock units and adapter-sleeve arrangements do not share one universal recommended shaft tolerance. Use the fitting and installation specifications for the exact unit.

Remove burrs and corrosion, clean the bearing seat, inspect for circumferential scoring, and check shaft roundness before fitting a new unit. Do not try to compensate for substantial shaft wear by overtightening set screws. Tightening torque and lubrication should follow the manufacturer’s instructions.

Mounted Bearing Installation: H7 Standards

Frequently Asked Questions

Are metric and inch pillow block bearings interchangeable?

No, not solely because they use the same housing family. The nominal bore and permissible shaft fit must match; also verify the mounting dimensions and locking arrangement.

Can pillow block bearings from different brands be swapped?

Sometimes, but the shared series designation alone is not sufficient. Compare the exact dimension drawings, locking arrangement, seals, load ratings and mounting hardware before substitution.

Can I replace only the UC insert bearing?

In many mounted-bearing units, the insert is replaceable. Confirm the housing seat diameter, insert width, bearing type, sealing arrangement and manufacturer compatibility before selecting an insert.

What if two units have the same bore but different bolt spacing?

They are not drop-in mounting replacements. You must select a housing with matching mounting geometry or verify that the equipment can be properly redesigned and re-aligned.

Does a P205 housing marking tell me the shaft size?

Not necessarily. The housing family may accept compatible metric and inch-bore inserts. Read the full insert designation and measure the shaft before ordering.

Choosing the Right Unit

For replacement work, identify the existing unit, measure the shaft, and confirm d, H, J and L against a dimension drawing. For new designs, calculate bearing load and life requirements before specifying the housing. Use the reference charts as a shortlist rather than the final purchase specification.

Browse LILY Bearing Pillow Block Bearings

Technical reference: nominal housing comparisons have been checked against NTN-SNR bearing-unit specifications. Load ratings and shaft fitting requirements are product-specific. Verify all critical dimensions and performance ratings on the final supplied product drawing.