Pillow block bearing sizes are identified by nominal shaft bore diameter, but housing dimensions also determine whether a unit will fit. The UCP200 size charts below cover metric and inch-bore units, including shaft diameter (d), center height (H), housing length (L) and nominal mounting-hole spacing (J).
Quick Answer
Metric — UCP205
25 mm
Nominal shaft diameter
Inch — UCP205-16
25.4 mm
1-inch nominal shaft diameter
The nominal bore difference is 0.4 mm. These bore sizes are not interchangeable. For replacement, check the full model number, shaft tolerance and mounting dimensions before ordering.
Pillow Block Bearing Size Chart (Metric and Inch)
These are reference dimensions for conventional UCP200 cast-iron, set-screw mounted bearing units. Nominal housings and accessories can differ by manufacturer or configuration. Dimensions are not manufacturing tolerances; consult the drawing of the exact product you plan to use.
UCP200 Series Size Chart (Metric)
Unit | Bore d (mm) | Center H (mm) | Length L (mm) | Bolt J (mm) | Bolt |
|---|---|---|---|---|---|
UCP201 | 12 | 30.2 | 127 | 95 | M10 |
UCP202 | 15 | 30.2 | 127 | 95 | M10 |
UCP203 | 17 | 30.2 | 127 | 95 | M10 |
UCP204 | 20 | 33.3 | 127 | 95 | M10 |
UCP205 | 25 | 36.5 | 140 | 105 | M10 |
UCP206 | 30 | 42.9 | 165 | 121 | M14 |
UCP207 | 35 | 47.6 | 167 | 127 | M14 |
UCP208 | 40 | 49.2 | 184 | 137 | M14 |
UCP209 | 45 | 54 | 190 | 146 | M14 |
UCP210 | 50 | 57.2 | 206 | 159 | M16 |
UCP211 | 55 | 63.5 | 219 | 171 | M16 |
UCP212 | 60 | 69.8 | 241 | 184 | M16 |
UCP213 | 65 | 76.2 | 265 | 203 | M20 |
UCP214 | 70 | 79.4 | 266 | 210 | M20 |
UCP215 | 75 | 82.6 | 275 | 217 | M20 |
Data note: Nominal UCP200 envelope dimensions are cross-checked against published NTN-SNR bearing-unit references. UCP212 uses H 69.8 mm, L 241 mm and J 184 mm; UCP213 uses H 76.2 mm, L 265 mm and J 203 mm; UCP214 uses H 79.4 mm, L 266 mm and J 210 mm. The final product drawing governs fit and interchangeability.
UCP200 Series Size Chart (Inch Bore)
Inch-bore suffixes commonly specify the bore in sixteenths of an inch; some catalogs use a three-digit alternative such as -100 for 1 in. The H, L and J columns below are approximate conversions of the metric-family reference dimensions, not measured inch-product specifications. Actual catalog dimensions and available suffixes may differ.
Unit | Bore (fraction) | Bore (decimal in) | Bore (mm) | H (in) | L (in) | J (in) |
|---|---|---|---|---|---|---|
UCP201-8 | 1/2" | 0.500" | 12.7 | 1.189 | 5.000 | 3.740 |
UCP202-9 | 9/16" | 0.5625" | 14.2875 | 1.189 | 5.000 | 3.740 |
UCP202-10 | 5/8" | 0.625" | 15.875 | 1.189 | 5.000 | 3.740 |
UCP203-11 | 11/16" | 0.6875" | 17.4625 | 1.189 | 5.000 | 3.740 |
UCP204-12 | 3/4" | 0.750" | 19.05 | 1.311 | 5.000 | 3.740 |
UCP205-13 | 13/16" | 0.8125" | 20.6375 | 1.437 | 5.512 | 4.134 |
UCP205-14 | 7/8" | 0.875" | 22.225 | 1.437 | 5.512 | 4.134 |
UCP205-15 | 15/16" | 0.9375" | 23.8125 | 1.437 | 5.512 | 4.134 |
UCP205-16 / UCP205-100 | 1" | 1.000" | 25.4 | 1.437 | 5.512 | 4.134 |
UCP206-101 | 1-1/16" | 1.0625" | 26.9875 | 1.689 | 6.496 | 4.764 |
UCP206-102 | 1-1/8" | 1.125" | 28.575 | 1.689 | 6.496 | 4.764 |
UCP206-103 | 1-3/16" | 1.1875" | 30.1625 | 1.689 | 6.496 | 4.764 |
UCP206-104 | 1-1/4" | 1.250" | 31.75 | 1.689 | 6.496 | 4.764 |
UCP207-104 | 1-1/4" | 1.250" | 31.75 | 1.874 | 6.575 | 5.000 |
UCP207-105 | 1-5/16" | 1.3125" | 33.3375 | 1.874 | 6.575 | 5.000 |
UCP207-107 | 1-7/16" | 1.4375" | 36.5125 | 1.874 | 6.575 | 5.000 |
UCP208-108 | 1-1/2" | 1.500" | 38.1 | 1.937 | 7.244 | 5.394 |
UCP208-109 | 1-9/16" | 1.5625" | 39.6875 | 1.937 | 7.244 | 5.394 |
UCP209-110 | 1-5/8" | 1.625" | 41.275 | 2.126 | 7.480 | 5.748 |
UCP209-112 | 1-3/4" | 1.750" | 44.45 | 2.126 | 7.480 | 5.748 |
UCP210-114 | 1-7/8" | 1.875" | 47.625 | 2.252 | 8.110 | 6.260 |
UCP210-200 | 2" | 2.000" | 50.8 | 2.252 | 8.110 | 6.260 |
UCP211-203 | 2-3/16" | 2.1875" | 55.5625 | 2.500 | 8.622 | 6.732 |
UCP215-48 | 3" | 3.000" | 76.2 | 3.252 | 10.827 | 8.543 |
Note: UCP206-104 and UCP207-104 both have a 1-1/4 in nominal bore but use different housings. A matching bore does not establish housing interchangeability. Verify the bolt size and hole geometry in the product drawing.
UCP205, UCP206, UCP207 and UCP208 Housing Dimensions
The following values come from the linked LILY product specifications. Use these catalog dimensions rather than the converted reference values when selecting these particular units.
LILY model | Bore | H | L | Bolt center range | Bolt |
|---|---|---|---|---|---|
25 mm | 36.5 mm | 140 mm | 95–114 mm | M10 | |
1 in | 1.4375 in | 5.5 in | 3.75–4.5 in | 3/8 in | |
30 mm | 42.9 mm | 165 mm | 113–129 mm | M14 | |
35 mm | 47.6 mm | 167 mm | 119–135 mm | M14 | |
40 mm | 49.2 mm | 184 mm | 124–149 mm | M14 |
The bolt center range is the minimum and maximum center-to-center spacing listed in the product catalog, not a tolerance on the nominal J dimension. Check mounting-slot geometry and fastener clearance as well.
Key Pillow Block Bearing Dimensions Explained
Bore (d) is the nominal shaft diameter. Center height (H) is measured from the housing mounting surface to the shaft centerline. J is the nominal center-to-center mounting-hole spacing; slotted holes may allow a range of bolt positions. Housing length (L) is the overall base length.

Dimension | Symbol | Selection check |
|---|---|---|
Shaft bore | d | Match the measured shaft and specified fit |
Center height | H | Maintain the intended shaft centerline |
Bolt-hole spacing | J | Match the existing mounting pattern |
Overall housing length | L | Check clearance on the machine frame |
Housing width / bolt slots | A / N | Check mounting footprint and fastener clearance |
Symbols are not universal across all catalogs: compare the dimension drawing, not only its letter codes. A nominal difference in H or J can prevent drop-in replacement even when two units accept the same shaft.
How to Read a Pillow Block Bearing Model Number
UCP205 is commonly assembled from a UC205 insert bearing and P205 pillow-block housing. In this family, 05 identifies a nominal 25 mm bore; UCP206 corresponds to 30 mm and UCP207 to 35 mm. UCP201 (12 mm), UCP202 (15 mm) and UCP203 (17 mm) are exceptions to the size-code-times-five rule.

For inch variants, check the full designation: UCP205-14 denotes 7/8 in and UCP205-16 denotes 1 in under the sixteenths convention. In catalogs using the three-digit convention, -107 denotes 1-7/16 in. A UC size chart describes the insert bearing, including bore, outside diameter and ring widths; a UCP size chart describes the complete mounted unit, including housing and mounting dimensions.
Other Common Mounted-Bearing Prefixes
Prefix | Typical configuration |
|---|---|
UCP | Two-bolt pillow block |
UCPA | Tapped-base pillow block |
UCPH | Higher-center pillow block |
UCF | Four-bolt square flange |
UCFL | Two-bolt oval flange |
UCT | Take-up unit |
Pillow Block vs. Flange Units: Selection Guide
How to Measure Pillow Block Bearings
Measure the Shaft Diameter
Isolate the equipment and prevent unintended movement. Measure the shaft at more than one axial location and in two perpendicular directions using a calibrated micrometer. Check for wear, taper and out-of-roundness; do not round an unknown shaft to the nearest nominal inch or millimeter.
Measure the Center Height
Measure the perpendicular distance from the mounting surface to the shaft centerline (H). If the shaft is parallel to the mounting surface, measure vertically to its top and subtract half the shaft diameter.
Center height calculation
H = T − d/2
H = 49.0 − 25.0/2 = 36.5 mm
T is the distance from the mounting surface to the top of the shaft; d is the shaft diameter. The shaft axis must be parallel to the mounting surface.
Check Mounting Dimensions
Measure the mounting-bolt centers (J), housing length (L), base and slot clearances. Compare the results with the exact product drawing.
Identify the Bearing and Housing
Record the full insert and housing designations, including any bore or locking suffixes. A housing marking alone does not establish shaft size.
Check Operating Requirements
Compare shaft fit, locking method, bearing load rating, operating speed and sealing arrangement. An accurate nominal bore by itself is not enough to select a safe substitute.
A 3/4 in shaft measures 19.05 mm, and a 1-1/2 in shaft measures 38.1 mm. Neither should be rounded to the nearest metric bore when selecting a replacement.
UCP200 vs. UCP300: What Changes?
For the same nominal shaft bore, a UCP300-family unit generally uses a larger insert and housing than its UCP200 counterpart. As a documented example, an NTN-SNR UCP205 has H = 36.5 mm, J = 105 mm and L = 140 mm, whereas NTN-SNR UCP305 has H = 45 mm, J = 132 mm and L = 175 mm. These are manufacturer-specific reference dimensions, not a universal interchangeability guarantee.
NTN-SNR reference | UCP205 | UCP305 |
|---|---|---|
Nominal shaft bore | 25 mm | 25 mm |
Center height H | 36.5 mm | 45 mm |
Bolt spacing J | 105 mm | 132 mm |
Housing length L | 140 mm | 175 mm |
Do not change series using a fixed percentage of the catalog dynamic load rating. Bearing life and suitability depend on the equivalent load, speed, operating conditions, reliability requirement and the manufacturer’s rating method. Check the actual housing footprint before assuming a larger series will fit.
Load Capacity and Performance of Pillow Block Bearings
Shaft Fit, Surface Condition and Installation
Shaft tolerance depends on the insert, locking system, loading and manufacturer. Set-screw mounted inserts, eccentric-lock units and adapter-sleeve arrangements do not share one universal recommended shaft tolerance. Use the fitting and installation specifications for the exact unit.
Remove burrs and corrosion, clean the bearing seat, inspect for circumferential scoring, and check shaft roundness before fitting a new unit. Do not try to compensate for substantial shaft wear by overtightening set screws. Tightening torque and lubrication should follow the manufacturer’s instructions.
Mounted Bearing Installation: H7 Standards
Frequently Asked Questions
Are metric and inch pillow block bearings interchangeable?
No, not solely because they use the same housing family. The nominal bore and permissible shaft fit must match; also verify the mounting dimensions and locking arrangement.
Can pillow block bearings from different brands be swapped?
Sometimes, but the shared series designation alone is not sufficient. Compare the exact dimension drawings, locking arrangement, seals, load ratings and mounting hardware before substitution.
Can I replace only the UC insert bearing?
In many mounted-bearing units, the insert is replaceable. Confirm the housing seat diameter, insert width, bearing type, sealing arrangement and manufacturer compatibility before selecting an insert.
What if two units have the same bore but different bolt spacing?
They are not drop-in mounting replacements. You must select a housing with matching mounting geometry or verify that the equipment can be properly redesigned and re-aligned.
Does a P205 housing marking tell me the shaft size?
Not necessarily. The housing family may accept compatible metric and inch-bore inserts. Read the full insert designation and measure the shaft before ordering.
Choosing the Right Unit
For replacement work, identify the existing unit, measure the shaft, and confirm d, H, J and L against a dimension drawing. For new designs, calculate bearing load and life requirements before specifying the housing. Use the reference charts as a shortlist rather than the final purchase specification.
Browse LILY Bearing Pillow Block Bearings
Technical reference: nominal housing comparisons have been checked against NTN-SNR bearing-unit specifications. Load ratings and shaft fitting requirements are product-specific. Verify all critical dimensions and performance ratings on the final supplied product drawing.