A useful bearing calculation ends with a decision: does the selected bearing or matched set meet the required operating life and withstand the maximum expected load? This guide follows that calculation from shaft forces to equivalent loads, life and static safety. It explains where SKF, FAG and NSK factors differ and which data must be selected before using a formula.
For the underlying load directions and capacity terminology, read Understanding Axial and Radial Load Capacity in Angular Contact Ball Bearings. Here, the focus is the next step: turning a defined machine load case into a defensible bearing selection.
Start with the Calculation Sequence
First define the calculation object: one bearing, an adjacent matched set, or one support in a shaft with separated bearings. Identify the exact designation, contact angle and arrangement. Then resolve the actual bearing forces, select the applicable coefficients, calculate dynamic and static equivalent loads separately, and compare the resulting life and static safety with the design requirements.
Step | What to establish |
|---|---|
1 Determine loads | Resolve support reactions, external thrust, induced axial forces and preload for each operating condition. |
2 Select the method | Match the brand, series, angle, arrangement and rating basis to the manufacturer’s calculation data. |
3 Calculate equivalent loads | Calculate P for operating conditions and P₀ for the governing maximum simultaneous load case. |
4 Calculate performance | Use the corresponding C and C₀ to calculate basic rating life and static safety. |
5 Make the decision | Compare with specified requirements and complete the remaining operating and mounting checks. |
P is the equivalent dynamic load used for fatigue-life calculation. P₀ is the equivalent static load used to assess the risk of permanent contact deformation. They serve different checks and are not added together. A rotating bearing may need both checks.
For a closer look at the difference between dynamic and static ratings, see our guide to static vs. dynamic bearing loads.
Calculation | Expression | Meaning |
|---|---|---|
Basic rating life | L₁₀ = (C/P)³ | Millions of revolutions for ball bearings |
Life at constant speed | L₁₀h = 10⁶(C/P)³ / (60n) | Hours at speed n in r/min |
Static safety | s₀ = C₀/P₀ | Compare with the required static safety factor |
Basic rating life represents 90 percent reliability under the rating-life model. Lubrication, contamination, reliability targets and material fatigue limits may require an adjusted-life assessment as well.
Determine the Forces Before Looking Up Factors
Fᵣ and Fₐ are actual bearing loads from the machine analysis. C and C₀ are manufacturer ratings for the selected calculation object. For example, a radial dynamic rating of 5,600 N supplies C, not Fᵣ. Resolve the machine forces and moments to obtain the radial reactions at the supports; determine which support locates the shaft axially and how thrust reaches it.
Why Bearing Axial Load Can Differ from External Thrust
A radial reaction in a single-row angular contact bearing produces an internal axial force component. Consider two opposed single bearings at separate shaft supports, with no external thrust. Radial loading still generates internal axial forces at their inclined contacts. Opposing bearing reactions must establish axial equilibrium, so setting each bearing’s Fₐ to zero would be incorrect. The manufacturer’s induced-force rules and the actual arrangement determine the forces; the internal components are not extra external forces to add to the shaft load.
Preload introduces another load path. Under SKF’s stated approximation for an interference-preloaded super-precision pair loaded axially, let mounted preload Gₘ = 300 N and external axial force Kₐ = 300 N. Because Kₐ ≤ 3Gₘ, the applicable relationship gives:
Fₐ = Gₘ + 0.67Kₐ
Fₐ = 300 + 0.67 × 300
Fₐ = 501 N
Here 501 N is the axial-load input prescribed by that approximation, rather than the external 300 N or the simple sum of 600 N. This illustration assumes the specific mounted pair and axial-loading conditions covered by SKF’s method. It is not a rule for combining external thrust, induced force and preload in every arrangement. Spring preload and high-speed thermal effects require their own treatment.
After installation, verify that the intended preload is achieved; see How to Check Angular Contact Bearing Preload and Runout After Installation.
Technical basis SKF Super-precision bearings catalogue, March 2016 edition, Equivalent bearing loads and preload relationships; NSK Rolling Bearings E1103c Part A, section 4.4.2, internal axial force components.
Use Different Load Cases for Life and Static Safety
Life calculation uses operating loads and the number of revolutions spent at each load. Static assessment uses the most severe credible simultaneous forces, including short overloads or shocks where relevant. In this guide F₀ᵣ and F₀ₐ identify the static-check forces, following FAG’s notation. Do not combine independent maxima that cannot occur together.
For discrete operating conditions with approximately constant load and speed in each interval, first calculate Pᵢ for each condition. A revolution-weighted equivalent load for the ball-bearing basic-life model is:
Peq = [Σ(Pᵢ³ × nᵢ × tᵢ) / Σ(nᵢ × tᵢ)](1/3)
Use this with total operating time and the time-weighted average speed, or accumulate life consumption by condition. A changing preload or contact distribution must be resolved within each load case before this averaging step.
Choose the Arrangement and Rating Basis

For available bearing types and configurations, explore our angular contact ball bearings product range.
The actual fits and mounting structure must provide the required axial freedom at B; retention and floating details are omitted from the schematic.
Combined illustration in upper-half axial section. Panel A compares DB, DF and DT pairing arrangements. Panel B shows a shaft support and loading example: A uses a DB locating pair, while B carries radial load and permits axial displacement. Panel B is a support layout, not another pairing type. Black dashed lines show contact/load directions. The illustrated 30-degree contact angle is not a specification for any particular bearing.
A single row carries axial load in one direction. In DT, two similarly oriented bearings share load in that direction and require suitable opposing axial support. DB and DF use opposed orientations and can locate the shaft axially in both directions. Their load distribution differs from a single row, which is why their low-ratio equivalent-load branch can retain an axial term.
An adjacent matched DB/DF set at one support is one calculation object when the manufacturer supplies a set method. Two single bearings separated along a shaft are different supports: resolve their individual radial reactions and induced axial forces before checking each bearing. Sharing the labels O or X does not make the two situations interchangeable.
For more on pairing configurations and preload selection, see our angular contact bearings guide.
Keep Loads and Ratings on the Same Basis
A pair-level equivalent load must be used with the manufacturer’s corresponding pair rating. A per-bearing load must be used with that bearing’s rating. Do not use a single-bearing C with a pair-level P, add two single-bearing ratings, or divide the load by two after already using a set formula. If the catalogue requires conversion from single-bearing to set ratings, apply its rules for that series and arrangement once. Some spindle methods evaluate the most heavily loaded bearing instead of the complete set.
Apply the Dynamic and Static Load Equations
Single Rows and Tandem Arrangements
For the applicable single-row and DT methods, select the branch using the actual load ratio and the specified limit e:
When Fₐ/Fᵣ ≤ e
P = Fᵣ
When Fₐ/Fᵣ > e
P = XFᵣ + YFₐ
X is the dynamic radial factor and Y the dynamic axial factor. In the corresponding static method, Y₀ is the static axial factor:
P₀ = max(F₀ᵣ, 0.5F₀ᵣ + Y₀F₀ₐ)
Back to Back and Face to Face Sets
When Fₐ/Fᵣ ≤ e
P = Fᵣ + Y₁Fₐ
When Fₐ/Fᵣ > e
P = XFᵣ + Y₂Fₐ
P₀ = F₀ᵣ + Y₀F₀ₐ
Y₁ applies in the low-ratio branch and Y₂ in the high-ratio branch. For an applicable NSK 30° calculation with Fᵣ = 2,000 N and Fₐ = 400 N, the ratio is 0.20, below e = 0.80. The single/DT expression gives P = 2,000 N; the DB/DF set expression gives P = 2,000 + 0.78 × 400 = 2,312 N. This compares formula inputs, not the relative life of two designs: their ratings and internal load distributions also differ.
NSK angle | e | Single/DT X | Single/DT Y | DB/DF Y₁ | DB/DF X | DB/DF Y₂ |
|---|---|---|---|---|---|---|
25° | 0.68 | 0.41 | 0.87 | 0.92 | 0.67 | 1.41 |
30° | 0.80 | 0.39 | 0.76 | 0.78 | 0.63 | 1.24 |
40° | 1.14 | 0.35 | 0.57 | 0.55 | 0.57 | 0.93 |
Technical basis NSK Rolling Bearings E1103c Part C, single-row angular contact bearing and matched-pair sections; E1254 Super Precision Bearings, Table 1.1. These rows apply only to the listed 25°, 30° and 40° contact-angle methods, not to 15° or 18° bearings. For the applicable 30° DB/DF static method, Y₀ = 0.66.
FAG Forty Degree Bearings
For the FAG 40° single-row scope described in the medias Dimensioning module, e = 1.14. The high-ratio single/DT branch uses X = 0.35 and Y = 0.57. The corresponding adjacent O/X pair uses Y₁ = 0.55, X = 0.57 and Y₂ = 0.93. These are not general factors for FAG 15°, 25° or all super-precision bearings.
For its 40° single-bearing static calculation, FAG specifies P₀ = F₀ᵣ when F₀ₐ/F₀ᵣ ≤ 1.9, and P₀ = 0.5F₀ᵣ + 0.26F₀ₐ above that limit. For the corresponding O/X pair, P₀ = F₀ᵣ + 0.52F₀ₐ. Use the stated coefficients and branch conditions for the selected product.
Technical basis Schaeffler medias, Single row angular contact ball bearings, Dimensioning, 40° contact-angle cases; online technical module rather than a dated print edition.
SKF’s standard single-row Loads module uses the same general branch structure but directs factor selection to the product technical data. Select e, X and Y for the exact SKF designation instead of transferring the numerical NSK or FAG row.
Use Series Specific Factors for Double Row Bearings
Applicable double-row designs use the DB/DF-style dynamic branches above and P₀ = F₀ᵣ + Y₀F₀ₐ. Their two rows form one bearing, so use that complete bearing’s product ratings. The following examples show how series selection changes the factors.
Brand and scope | e | X | Y₁ | Y₂ | Y₀ |
|---|---|---|---|---|---|
FAG 25° double row | 0.68 | 0.67 | 0.92 | 1.41 | 0.76 |
FAG 30° double row | 0.80 | 0.63 | 0.78 | 1.24 | 0.66 |
FAG 35° double row | 0.95 | 0.60 | 0.66 | 1.07 | 0.58 |
FAG 45° double row | 1.34 | 0.54 | 0.47 | 0.81 | 0.44 |
SKF 32 A and 33 A | 0.80 | 0.63 | 0.78 | 1.24 | 0.66 |
SKF 33 D | 1.34 | 0.54 | 0.47 | 0.81 | 0.44 |
SKF 33 DNRCBM | 1.14 | 0.57 | 0.55 | 0.93 | 0.52 |
NSK 32..BTNG and 33..BTNG | 0.68 | 0.67 | 0.92 | 1.41 | 0.76 |
NSK 32..J and 33..J | 0.86 | 0.62 | 0.73 | 1.17 | 0.63 |
Technical basis FAG rows: Schaeffler medias, Double row angular contact ball bearings, Dimensioning, grouped by contact angle. SKF rows: Rolling bearings catalogue, printed page 400, Table 10, historical series examples; confirm current product data before use. NSK rows: Double Row Ball Bearings and Customized Ball Bearings, printed page 28, BTNG and J series separately. The SKF and NSK extracts are identified by catalogue section and page; no unverified publication year is assigned.
Handle Super Precision and Four Point Designs Separately
Super Precision Bearings and Preload
Super-precision describes a product or accuracy class and can overlap with single-row and paired construction. For spindle bearings, determine mounted preload and the operating contact-load distribution first. The SKF preload example earlier illustrates why a small external thrust does not imply a small internal axial load.
Some 15° SKF and NSK factor tables depend on a parameter involving f₀, Fₐ and the specified static rating. SKF uses f₀Fₐ/C₀ for the single/DT table and 2f₀Fₐ/C₀ for the DB/DF table. NSK Table 1.1 uses if₀Fₐ/C₀ᵣ, with i = 1 for single/DT and i = 2 for DB/DF. Read the rating basis exactly as defined in that table; do not substitute a converted set rating into the lookup parameter without checking the instructions.
For a correctly calculated SKF 15° DB/DF lookup parameter of 0.714, the table gives e = 0.43, X = 0.72, Y₁ = 1.46, Y₂ = 2.11 and Y₀ = 0.92.
At Fₐ/Fᵣ = 0.50, use the high-ratio branch:
P = 0.72Fᵣ + 2.11Fₐ
At Fₐ/Fᵣ = 0.30, use the low-ratio branch:
P = Fᵣ + 1.46Fₐ
For intermediate lookup parameters, follow the manufacturer’s interpolation instructions.
Technical basis SKF Super-precision bearings, March 2016 catalogue, printed page 191, Tables 37 and 38; 15° designation suffixes CD, CE and CB. NSK Super Precision Bearings E1254, printed pages 192–193, Table 1.1, corresponding 15° single and matched-bearing rows.
For the SKF 18° FE, FW and FB scope, the factors are:
Single/DT: e = 0.57; X = 0.43; Y = 1.00; Y₀ = 0.42.
DB/DF: e = 0.57; Y₁ = 1.09; X = 0.70; Y₂ = 1.63; Y₀ = 0.84.
The DB/DF low-ratio branch is:
P = Fᵣ + 1.09Fₐ
The DB/DF high-ratio branch is:
P = 0.70Fᵣ + 1.63Fₐ
Technical basis SKF Super-precision bearings, March 2016 catalogue, printed page 191, Tables 37 and 38, 18° FE, FW and FB rows.
NSK’s 18° dynamic factors vary with its load parameter and should be selected from E1254 Table 1.1. Its Table 2.1 distinguishes single-row and double-row static coefficient columns: 0.46 and 0.92 respectively in the 18° row. A double-row table column must not be relabelled as a universal DB/DF set coefficient. For a matched NSK spindle set, use the set or individual-bearing method prescribed for that series and the corresponding rating basis. This guide therefore does not assign the double-row value to every 18° DB/DF set.
Technical basis NSK Super Precision Bearings E1254, Table 1.1 and printed page 198, Table 2.1; dynamic and static tables have different structural headings.
FAG SP 1 also defines P₀* for its fatigue-strength assessment: it uses a static-equivalent form with dynamic operating forces. P₀* is neither P in the basic rating-life equation nor P₀ for the maximum static load case. A spindle design should follow the complete SP 1 method rather than mix these quantities.
Technical basis FAG Super Precision Bearings SP 1, printed pages 39–42, fatigue strength and static safety sections.
Four Point Contact Bearings
First decide whether the bearing carries combined loads as a locating bearing or carries thrust only beside a separate radial bearing. In a specified thrust-only arrangement, radial clearance around the outer ring prevents the four-point bearing from taking the radial support load. Merely omitting Fᵣ from the calculation does not create that mounting condition.
For SKF four-point bearings carrying combined loads, select factors from the specific product data:
P = Fᵣ + Y₁Fₐ
Use this branch when Fₐ/Fᵣ ≤ e.
P = XFᵣ + Y₂Fₐ
Use this branch when Fₐ/Fᵣ > e.
P₀ = F₀ᵣ + Y₀F₀ₐ
For the specified thrust-only mounting:
P = 1.07Fₐ
Applicable to QJ 2, QJ 3 and QJ 10.
P = 0.81Fₐ
Applicable to QJ 12. The recommended operating load ratios are separate from the branch limit e.
Technical basis SKF Rolling bearings, Four-point contact ball bearings, Loads module, combined-load and thrust-only mounting cases.
Historical FAG HR 1 four-point data use e = 0.95, Y₁ = 0.66, X = 0.60, Y₂ = 1.07 and static Y₀ = 0.58. The stated minimum axial loading and mounting conditions remain part of that method; these historical values do not replace current product data. NSK’s applicable QJ product tables use axial ratings Cₐ and C₀ₐ with Pₐ = Fₐ and P₀ₐ = F₀ₐ. Those axial-basis entries are not a general permission to ignore radial force in a combined-load design.
Technical basis FAG HR 1, four-point contact bearing section, printed page 353, historical catalogue extract. NSK Rolling Bearings E1103c Part C, QJ four-point contact product tables. Preserve each source’s radial or axial rating basis.
Work Through a Complete Bearing Selection Example
Define the Shaft and Requirements
Consider a hypothetical shaft with an adjacent NSK-type 30° DB pair at locating support A and a radially supporting, axially floating bearing at B. The span is 200 mm. A 4,000 N radial force acts at midspan with no other radial forces or moments, giving 2,000 N radial reaction at each support. A 1,800 N external axial force is transmitted entirely to A because B is free to float axially.
Use the stated forces, coefficients and ratings consistently for the complete matched pair. This teaching example assumes no intentional preload and neglects internal setting effects. It evaluates the pair as a unit; a preloaded spindle requires a separate internal-load analysis.
Input | Normal running | Maximum static check |
|---|---|---|
Applied midspan radial force | 4,000 N | 6,000 N |
Support A radial reaction | Fᵣ = 2,000 N | F₀ᵣ = 3,000 N |
Axial force at locating support A | Fₐ = 1,800 N | F₀ₐ = 3,000 N |
Operating speed | 3,000 r/min | Peak event treated separately |
The running load is constant for this basic-life example. The maximum-load event is assumed rare enough to make a negligible contribution to fatigue cycles, but its simultaneous radial and axial forces govern the static check. If it repeats frequently, include it in the operating load spectrum too.
For the complete DB pair, assume C = 20,000 N and C₀ = 15,000 N. These are hypothetical set ratings, not real-model data or the ratings of each bearing. The design requires basic rating life L₁₀h ≥ 10,000 hours and static safety s₀ ≥ 2.0. The latter is an assumed project criterion, not a universal NSK minimum.
Calculate the Operating Equivalent Load
Fₐ/Fᵣ = 1800/2000 = 0.90 > e = 0.80
Select the NSK 30° DB/DF high-ratio coefficients X = 0.63 and Y₂ = 1.24:
P = 0.63Fᵣ + 1.24Fₐ
P = 0.63 × 2000 + 1.24 × 1800
P = 3492 N
Check Basic Rating Life
L₁₀ₕ = [10⁶ / (60 × 3000)] × (20000/3492)³ ≈ 1044 hours
The calculated 1,044 hours is below the required 10,000 hours, so the proposed pair fails the basic-life target. Holding the load and speed fixed, the required dynamic set rating is approximately:
Crequired = 3492 × [(60 × 3000 × 10000) / 10⁶](1/3) ≈ 42478 N
This is a screening target for a candidate with a compatible calculation method. A different bearing may change e, the axial coefficients, preload or load distribution, so its P and life must be recalculated rather than reusing 3,492 N automatically.
For further guidance on the rating-life calculation, use the bearing life calculation resource.
Check the Maximum Load Case
Use the peak forces and the applicable NSK 30° DB/DF static coefficient Y₀ = 0.66:
P₀ = F₀ᵣ + 0.66F₀ₐ
P₀ = 3000 + 0.66 × 3000
P₀ = 4980 N
s₀ = 15000/4980 ≈ 3.01
The static result exceeds the assumed requirement of 2.0, so the pair passes this static criterion. It still fails the overall selection because its basic rating life is inadequate. Reassess bearing size or series, radial and axial force paths, speed, and duty cycle. Then verify lubrication, contamination and preload before accepting a revised design.
Avoid Errors That Change the Selection Result
Using single-bearing ratings for a pair is a common basis error. State the calculation object beside C, C₀, P and P₀ so an individual-bearing method cannot be mixed with a set method. Using running forces in the static check can hide a peak-load problem; using a rare peak continuously in the life calculation can misrepresent the duty cycle.
Another error is choosing a factor row before determining Fₐ. Resolve the induced-force or preload model first, calculate the required lookup parameter where applicable, and then select the branch. For a permitted pure-axial case, Fᵣ = 0; do not evaluate Fₐ/Fᵣ by dividing by zero. Use the applicable axial-load expression and its mounting restrictions.
Turn the Calculation into a Design Decision
Use forces, coefficients and ratings for the same bearing or matched set, then compare life and static safety with the design requirements. This example passes the peak-load safety target but fails the life target, so the selection must be revised.
Before release, also check permissible axial load, minimum load, speed, stiffness, thermal behaviour, lubrication, fits and mounting tolerances. Equivalent-load calculations do not replace these limits. Use the selected angular contact bearing product data and the arrangement-specific technical guidance to finish the design.
For spindle applications, review the available super-precision angular contact ball bearings and evaluate each candidate using its own product data.