Vacuum Pump Bearings
Vacuum pump bearings are engineered as the core component to achieve ultra-hign wacuum environments and stable operation. The design exceeds the limits of conventional bearings, tailored for extreme conditions:
●Micron-Level Precision:
Precision machining and dynamic balancing ensure rotor vibration below 0.05mm at ultra-hign speeds (>=15,000 RPM), preventing micro-leakage in vacuum chambers;
●Hign-Temperature & Hign-Speed Resistance:
Hybrid ceramic materials and silicon nitride rollers withstand continuous temperatures above 200°C, tripling lubrication lifespan;
●Longevity Under Heavy Loads:
Optimized raceway curvature and preload design double axial/radial load capacity, achieving over 20,000 hours of service life in semiconductor coating applications.
Precision Bearings for Demanding Vacuum Applications
LILY Bearings are trusted by global leaders in vacuum technology, including Edwards, Busch, and Ebara, to deliver unmatched reliability in critical pump systems.
Need customization?
✔️ Materiais ✔️ Vedantes ✔️ Dimensões
15+ years of OEM expertise ensures:
●Ultra-high vacuum (UHV) reliability
●Resistência Química
●Low heat & torque
Contact our engineers to discuss your specs
Dry Vacuum Pumps — Clean and oil-free for long-lasting durability

| Número da Peça | Diâmetro do Furo | Diâmetro Externo | Largura | Material da Esfera | Tipo de Vedação | Lubrificação | Material da Gaiola | Aplicação |
|---|---|---|---|---|---|---|---|---|
| C211HY1 | 55mm | 100mm | 21mm | Nitreto de Silício(HIP) | Um Lado Blindado, Um Lado Vedado | Fluorinated Lubricants | SPCC | Edwards Dry Vacuum Pump IH Series 1800/1000/600 |
| VCMP209ASP | 36.5mm | 85mm | 19mm | Nitreto de Silício(HIP) | Um Lado Blindado, Um Lado Vedado | Fluorinated Lubricants | SPCC | Edwards Dry Vacuum Pump IH Series / GXS Series |
| AB5058TY | 12mm | 14mm | 15mm | Nitreto de Silício(HIP) | Um Lado Blindado, Um Lado Vedado | Fluorinated Lubricants | SPCC | Alcatel A100L/103 Rear End, EBARA Motor End |
| VCMP114 | 45mm | 110mm | 19mm | Nitreto de Silício(HIP) | Um Lado Blindado, Um Lado Vedado | Fluorinated Lubricants | SPCC | Edwards Dry Vacuum Pump IXH/IH Series |
| C206SY7 SCB1216 |
30mm | 62mm | 16mm | Nitreto de Silício(HIP) | Um Lado Blindado, Um Lado Vedado | Fluorinated Lubricants | SPCC | Edwards Dry Vacuum Pump IH600/IQDP40/80 Series |
| VCMP 6007 | 35mm | 62mm | 14mm | Nitreto de Silício(HIP) | Aberto | Fluorinated Lubricants | SPCC | / |
| NU209 | 45mm | 85mm | 19mm | Nitreto de Silício(HIP) | / | Fluorinated Lubricants | Latão | / |
| NU211 | 55mm | 100mm | 21mm | Nitreto de Silício(HIP) | / | Fluorinated Lubricants | Latão | / |
| VCMP 6207 | 35mm | 72mm | 17mm | Nitreto de Silício(HIP) | Aberto | Fluorinated Lubricants | SPCC | Hanbell Roots Pump Free End |
| 3307 | 35mm | 80mm | 34.9mm | Nitreto de Silício(HIP) | / | Fluorinated Lubricants | SPCC | Hanbell Roots Pump Fixed End |
| VCMP212 | 45mm | 110mm | 22mm | Nitreto de Silício(HIP) | Um Lado Blindado, Um Lado Vedado | Fluorinated Lubricants | SPCC | Edwards Dry Vacuum Pump IXH/GXS Series |
| VCMP 6211 C3 | 55mm | 100mm | 21mm | Nitreto de Silício(HIP) | Aberto | Fluorinated Lubricants | SPCC | / |
| 7210ADB | 50mm | 90mm | 20mm | Nitreto de Silício(HIP) | Aberto | Fluorinated Lubricants | SPCC | Kashiyama SDL3600 Fixed End |
Core value
Designed for oil-free vacuum environments to avoid oil contamination sensitive scenarios (e.g. semiconductor, pharmaceutical equipment).
Points for Use
●Dust sealing: dry pumps are mostly used in dusty environments, check bearing seals regularly for deterioration (visual inspection every 500 hours is recommended);
●Lubrication compatibility: use only solid lubricants (e.g. molybdenum disulfide) or specified dry grease to avoid oil mist contamination of the vacuum chamber;
●Overheating warning: bearings need to be shut down for troubleshooting when the temperature rise is >80°C. Common causes are lubrication failure or rotor imbalance.
Adaptation Scenario
●Laboratory small vacuum system
●3D printing powder handling equipment
●Food packaging machinery
Turbomolecular Pumps — Extreme speed, ultra-high vacuum

| Número da Peça | Diâmetro do Furo | Diâmetro Externo | Largura | Material da Esfera | Tipo de Vedação | Lubrificação | Material da Gaiola | Aplicação |
|---|---|---|---|---|---|---|---|---|
| 7003 | 17mm | 35mm | 9.85mm | Nitreto de Silício(HIP) | Aberto | High-Temperature Greases | / | Magnetic Levitation Molecular Pump Lower Protective End Bearing |
| C104HY17 | 22mm | 42mm | 12mm | Nitreto de Silício(HIP) | Aberto | High-Temperature Greases | Phenolic Resin | Mechanical Molecular Pump Upper/Lower Ends |
Core value
Supports ultra-high speed rotation of molecular pump rotors (typically ≥60,000 RPM) to achieve 10-⁸ Pa class ultra-high vacuum.
Points for Use
●Dynamic balance calibration: dbearings need to be calibrated with a dynamic balancer after replacement (allowable residual vibration <0.01mm), otherwise it is easy to trigger resonance and damage the blades;
●Vacuum-compatible materials: only ceramic bearings or vacuum-coated steel bearings are used; outgassing of ordinary bearings will contaminate the vacuum level;
●Pre-tensioning force adjustment: the installation needs to be locked according to the manual torque, too tight leads to too fast temperature rise, too loose reduces the axial bearing capacity.
Adaptation Scenario
●Electron Microscope & Mass Spectrometer
●Vacuum Coaters & Ion Implantation Equipment
●Vacuum testing of aerospace components
Maintenance FAQ
Molecular pumps: vacuum drop of more than 20% or abnormally high starting current.
Advanced needs: dynamic balancer (required for molecular pumps), vacuum grease (specified models only).
Molecular pumps: 10,000-15,000 hours (30% longer at constant temperature up to 25°C).




